The 2650 load shackle has been designed for measuring tensile loads using double shear strain gauged element. The range is from 5 tonne to 100 tonne, with higher capacities available by request. The load pin is manufactured from high strength alloy steel and fitted with mild steel bobbin and anti-rotation plate. The load cell is used for tempory or permanent rope tension applications, or for under hook weighing, particularly in rugged and harsh conditions. It can be also be used at the dead end of a rope such as a winch or crane.

Specifications

ELECTRICAL

  • Recommended excitation 10 Vdc.
  • Maximum excitation 15 Vdc.
  • Output at rated load 2.0mV/V
  • Zero balance 5% of RL
  • Input impedance 700ohms +/-20
  • Output impedance 700ohms +/- 3
  • Insulation >10^9ohms
  • Compensation temp range 10 to 60 C
  • Safe temp range -30 to 70 C


MECHANICAL

  • Safe overload 150% of RL
  • Ultimate overload 300% of RL
  • Deflection <0.5mm
  • Cable type 4 core screened
  • Cable length 10 M
  • Sealing IP68

Accuracy

  • Non linearity & hystersis 1.0%
  • Non repeatability 0.25%
  • Zero return (after 30 mins). 0.08%
  • Temp effect/10deg C on zero 0.05%
  • Temp effect/10deg C on span 0.03%

Wiring


Drawing


Dimensions



ActiveLoad

Welcome to Active Load.

tel: +44 (0) 1491 680123

Active Load provides complete transducer solution designing and manufacturing strain gauge transducers.

Strain gauge transducers are designed to be Load Cells, Force Sensors, Torque Sensors, Pressure Transducers and any other strain related product.

Active Load will incorporate the strain gauge cells with a strain gauge amplifier to achieve an enhanced signal. Many of our strain gauge load cells are designed to be in the form of load monitoring pins to measure rope tension. Other forms taken are as load monitoring links and compressive load cell.