Pressure range from 10te to 100te
• Range 10te to 100te
• Stainless steel construction.
• Rugged and easily employed
• Sealed to IP68
Description
The 1740 Double ended load beam has full environmental protection and is built for rugged applications. The load cell is constructed from high strength stainless steel. A complete range covers the load capacities from 10te to 100 tonne. Each load cell can be fitted with loading plate assembly or other loading attachments. The load cell is built to the highest commercial standards that include temperature compensation over a wide temperature range.
Specification
ELECTRICAL
• Recommended excitation 10 Vdc.
• Maximum excitation 15 Vdc.
• Output at rated load 2.0mV/V
• Zero balance 5% of RL
• Input impedance 700ohms +/-20
• Output impedance 700ohm +/-3
• Insulation >10^9ohms
• Compensation temp range 10 to 60 C
• Safe temp range -30 to 70 C
MECHANICAL
• Safe overload 150% of RL
• Ultimate overload 300% of RL
• Deflection <0.5mm
• Cable type 4 core screened
• Cable length 6 M
• Sealed IP67
Accuracy
• Non linearity & hysteresis 0.15%
• Non repeatability <0.01%
• Zero return (after 30 mins). 0.04%
• Temp effect/10deg C on zero 0.02%
• Temp effect/10deg C on span 0.02%
Wiring

Drawing

Dimensions

Additional Notes
Specification may change without notice